13
No power indication
No display on operators console
Power on – no motion
No roll action
Material will not enter rolls
Material will not feed
Material feeds short
Material feeds long
Material camber
troubleshooting
Problem Cause Remedy
Disconnect off
Blown fuse
Master button in
Program fault
Faulty wiring
Program fault
Drive fault
Program error
No air
Low air pressure
Anti-backup closed
Feed roll adjusting mechanism
too close
Material too thick
Low roller force
Oily material
Program fault
Obstruction in die
Accel to fast
Lower roller force
Oily material
Obstruction in die
Feed signal to close to pilot release
High % max speed
Material slippery
Decel set too high
High roller force
Bad stock
Turn disconnect on
Check / replace fuse
Pull button out
Check lights on P.C.
Check plug on console
Check lights on drive
Check lights on servo drive readout
Check parameters
Check air line
Check air regulator
Open rolls
Open adjustment mechanism
Check servo parameters
Raise roller pressure
Clean material
Check parameters
Check die
Lower accel speed
Raise roller pressure
Clean material
Check die
Move feed signal input so rolls
are closed to feed
Lower % max feed speed
Lower % decel
Lower % decel
Lower roller pressure
Check stock at input for camber
Vedere la pagina 12